Журналы →  Chernye Metally →  2022 →  №8 →  Назад

90 years of the Department of Materials Science and Composite Materials of Volgograd State Technical University
Название Computer simulation of circular plastic compression of a lightning protection cable with an optical module
DOI 10.17580/chm.2022.08.10
Автор L. M. Gurevich, V. F. Danenko
Информация об авторе

Volgograd State Technical University, Volgograd, Russia:

L. M. Gurevich, Dr. Eng., Associate Prof., Head of the Dept. of Materials Science and Composite Materials, e-mail: mv@vstu.ru
V. F. Danenko, Cand. Eng., Associate Prof., Dept. of Materials Technology

Реферат

In the work, using computer simulation, the geometric parameters of the elements of a lightning protection cable (strands of the LK-О type) with an optical module at circular plastic compression are determined. A delay in the formation of side contacts (arch effect) between the wires of the outer layer of the strand of 1 + 9 + 9 structure with a dense lay of elements is established, which creates conditions for transferring pressure to the inner layers and causes a significant (up to 20 %) deformation of the optical module surface at a degree of compression of ql = 5.5 %. In this case, the filling level of inner layer gaps reaches a critical one, which contributes to the transition to the elongation deformation (drawing) of the wires and to a decrease in the longitudinal stiffness of the strand. Violation of the condition of tight laying of the strand elements by choosing the geometric dimensions of the wires during modeling, which ensure the presence of initial gaps between the layers, reduces the deformation on the surface of the optical module to ql = 7–8 % at a degree of compression ql = 6 %, which is explained by more intensive formation of lateral contacts between wires of the outer layer, reducing the radial component of the pressure transmitted inside the strand. It is shown that its reduction can also be achieved by increasing the number of wires in the layers. For a strand of 1 + 10 + 10 construction, in the presence of a gap between the inner layer and optical module, the deformation on the core surface is 3–4 % at a compression ratio of ql = 6.3 %, which ensures the operability of the optical module (core) after circular plastic compression and integrity of optical fibers.

Ключевые слова Lightning protection cable, optical module, wire, modeling, circular compression, deformation, side contacts, arch effect
Библиографический список

1. Ivanovskiy D. А. The use of an optical cable built into the ground wire to transfer information between the power system elements. Izvestiya vysshikh uchebnykh zavedeniy. Elektromekhanika. 2013. No. 1. pp. 33–35.
2. Yokoya M., Katsuragi Y., Goda Y., Nagata Y., Asano Y. Development of lightning-resistant overhead ground wire. IEEE Transactions on Power Delivery. 1994. Vol. 9. pp. 1517–1523.
3. Li J., Sun D. D. Notice of retraction: analysis on lightning strike damages to optical fiber composite overhead ground wire. International Conference on Industrial and Information Systems. 2009. pp. 39–44.
4. IEEE 1138–2021. IEEE Standard construction of composite fiber optic overhead ground wires (OPGW) for use on electric utility power lines. Applied : 05.11.2021. USA: Europian Standarts, 2021.
5. IEC 61396. Electrical mechanical and physical requirements and test methods of optical ground wire (OPGW). Applied : 01.01.2000. USA: International Electrotechnical Commission, 2000.
6. IEC 60794-4:2018. Optical fibre cables – part 4: sectional specification – aerial optical cables along electrical power lines. Edition 2.0. Published: 25.06.2018. USA: International Electrotechnical Commission, 2018.
7. GOST R 52266–2020. Fibre optical cables. General specifications. Introduced: 01.09.2020. Moscow: Izdatelstvo standartov, 2020.
8. Standard organization No. 56947007-33.180.10.174–2014. Optical cable built into a lightning protection cable, tension and support clamps, couplings for organizing fibre-optic line – aerial circuit on power lines with a voltage of 35 kV and above. General specifications. Introduced: 21.05.2014. Moscow: Izdatelstvo standartov, 2014.
9. Development of an optimal technology for the production of an OPGC design with 24 optical fibers and a diameter of not more than 11.5 mm. Available at: http://metsbytservis.ru/attachments/1.-razrabotka-optimalnoy-tehnologii-okgt.pdf (accessed: 29.07.2022).
10. Vlasov А. К., Fokin V. А., Petrovich V. V., Frolov V. I., Danenko V. F. On improving the service properties of ropes for lightning protection of overhead power lines. Stal. 2011. No. 7. pp. 78–81.
11. Gurevich L. М., Danenko V. F., Pronichev D. V., Trunov М. D. Computer simulation in designing the process of circular compression of a ground wire with an optical module. Izvestiya Volgogradskogo gosudarstvennogo tekhnicheskogo universiteta. 2015. No. 8. pp. 97–102.
12. Korchunov А. G., Medvedeva Е. М., Kharitonov V. А., Konstantinov D. V. The effect of compaction on the stress-strain state of prestressing strands. Chernye Metally. 2021. No. 11. pp. 50–54.
13. Danenko V. F., Gurevich L. M. On calculation of stress-strain state of steel closed ropes in extension and twisting. Part 1. Determination of generalized stiffness and deformation coefficients. CIS Iron and Steel Review. 2021. Vol. 22. pp. 20–25.
14. Korchunov A. G., Medvedeva E. M., Ivekeeva P. V., Konstantinov D. V. FEM study of internal stresses evolution in prestressing strands. CIS Iron and Steel Review. 2020. Vol. 20. pp. 21–24.
15. Ren Zhiqian, Yu Zongyue, Chen Xun. Model for taking into account the effect of elastoplastic damages on the strength of a wire rope. Journal of Mechanical Engineering Science. 2017. Vol. 53. No. 1. pp. 121–129.
16. Wenzheng D., Baozhu M., Zheng X., Dazhi C., Peng W. Finite element analysis on the wire breaking rule of 1×7IWS steel wire rope. MATEC Web of Conferences. 2017. Vol. 108. pp. 01002.
17. Standard of organization (STO) No. 71915393 – ТU 113 – 2011. Steel rope for protection of aerial power transmission lines from direct lighting strikes with optical connection cable. Introduced : 25.05.2011. Volgograd. «Severstal-metiz» JSC. 2011.
18. GOST 7372–79. Steel wire for ropes. Introduced: 01.01.1982. Moscow: Izdatelstvo standartov, 1979.
19. Standard of organization (STO) No. 71915393 – ТU 113 – 2014. Overhead ground-wire cable with built-in fiber-optic connection cable for protection of aerial power transmission lines from direct lighting strikes. Introduced : 23.04.2014. Moscow. «Metsbytservis» JSC. 2014.
20. Johnson G. R., Cook W. H. Fracture characteristics of three metals subjected to various strains, strain rates, temperatures, and pressures. Engineering fracture mechanics. 1985. Vol. 21. No. 1. pp. 31–48.
21. Malinovskiy V. А. Steel ropes. Part. 1. Odessa: Astroprint, 2001. 188 p.
22. Kharitonov V. А., Lapteva Т. А. Analysis of methods for assessing the degree of deformation of a strand during plastic compression. Modelirovanie i razvitie protsessov OMD. 2015. No. 21. pp. 105–109.
23. Glushko M. F., Malinovskiy V. А., Kobyakov Yu. V. et al. Author's certificate of the USSR, No. 867976. Applied: 04.02.1981. Published: 30.09.1981. Bulleten No. 36.
24. Kharitonov V. А., Ivantsov А. B., Lapteva Т. А. Regularities of wire strain distribution in a multilayer strand under circular calibrating compression. Izvestiya vuzov. Chernaya metallurgiya. 2019. Vol. 62. No. 9. pp. 691–697.

Language of full-text русский
Полный текст статьи Получить